| Type ARC 1550 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Welding range |
#4 to 3/4'', dia. 14 ga to 3/4" (M3 - M20 RD, dia. 2 to 19 mm) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Gas/Automation |
Series/Option |
| Welding material |
Mild steel, stainless steel |
| Welding rate |
3 to 35 studs/min (depending on application and stud dia.) |
|
|
|
|
| Welding current |
1,550 A |
| Current adjustment range |
500 to 1,550 A (500 A - 800 A - 1,000 A - 1,200 A - 1,550 A) |
| Welding time |
5 to 1,500 msec (stepless) |
|
|
|
|
| Primary power |
460 V, 3 phases, 50/60 Hz, 63 AT (alternative input voltages available) |
|
|
|
|
|
|
|
|
| Power source |
Transformer/Rectifier |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Connected load |
40 KVA (at 460 V mains) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Primary cable |
16.40', 1/0 (5 m, 6 mm²), 460 V ; max. cable length 98.42' (30 m), 1/0 (6 mm²) at 400 V |
|
|
| Cooling type |
F (temperature controlled cooling fan) |
| Protection class |
IP 23 |
Operational and storage conditions |
According to current standards |
| Dimension LxWxH |
18.11" x 15.74" x 28.74" (460 x 400 x 730 mm) (without handle) |
|
|
| Weight |
293.21 lbs (133 kg) |
|
|
|
|
|
|
|
|
|
|
| Order No. |
93-16-1552 (Gas) 93-16-1554 (Gas/Automation) |
|
| Description |
Application
-
Especially suitable for thicker sheets of about 2 mm or higher
Features
-
Microcontroller
-
Function monitoring
-
Display of error codes
-
Lift test
-
Power regulation
Safety
-
Integrated mains filter
-
Optimal for construction sites with large mains voltage fluctuations
-
EMC test
-
High-voltage test with log
-
Retriggering lock
-
Thermal monitoring of transformer
-
Temperature-regulated ventilator
-
Consistent separation of transformer and control unit
-
Control unit galvanically separated from welding lines
-
Optimal protection against external interferences
-
Protection class IP 23
|
|