| Type ARC 500 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Welding range |
#4 to 7/16", dia. 14 ga to 5/16" (M3 to MR10, dia. 2 to 8 mm) |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Welding material |
Mild steel, stainless steel |
| Welding rate |
5 to 15 studs/min (depending on application and stud dia.) |
|
|
|
|
| Welding current |
580 A |
|
|
| Welding time |
5 to 350 msec |
|
|
|
|
| Primary power |
230/460 V 3 phases, 50/60 Hz, 50/35 AT or 575 V, 3 phases, 50/60 Hz, 25 AT (alternative input voltages available) |
|
|
|
|
|
|
|
|
| Power source |
Transformer/Rectifier |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
| Cooling type |
F (temperature controlled cooling fan) |
| Protection class |
IP 23 |
Operational and storage conditions |
According to current standards |
| Dimension LxWxH |
18.50" x 9.06" x 8.66" (470 x 230 x 220 mm) without handle |
|
|
| Weight |
68.34 lbs (31 kg) |
|
|
|
|
|
|
|
|
|
|
| Order No. |
230/460 V: 93-16-0401A 575 V: 93-15-0401A |
|
| Description |
Application
-
Especially suitable for thicker sheets of about 2 mm or higher
-
ISO - especially suitable for attaching cut-to-length ARC-ISO and Fiberfix pins; also material with high heat resistance; excellent for insulation applications in building construction and fire-resistant insulation (FRI).
Features
-
Microcontroller
-
Function monitoring
-
Display of error codes
-
Lift test
Safety
-
Integrated mains filter
-
Optimal for construction sites with large mains voltage fluctuations
-
EMC test
-
High-voltage test with log
-
Retriggering lock
-
Thermal monitoring of transformer
-
Temperature-regulated ventilator
-
Consistent separation of transformer and control unit
-
Control unit galvanically separated from welding lines
-
Cooling-air tunnel
-
Optimal protection against external interferences
-
Protection class IP 23
|
|